Indoor Cat6 UTP

Indoor Cat6 UTP

Product Description

Describe
Rated temperature 75℃ description
Rated temperature 75℃
Standard UL444, TIA/EIA568B, ISO/IEC11801
23 awg wire gauge
A single bare copper conductor
Insulating high density polyethylene
Line of 4
Sheathed PVC/low smoke halogen free (as required)
Tear the rope as needed
Electrical properties
1.0~ 250.0mhz characteristic impedance (ohms) 100±15
1.0~ 250.0mhz delay difference (ns/100m) ≤45
At 20℃, the maximum dc resistance (ohms/km) of the conductor is less than or equal to 65.8
Conductor resistance unbalance (%) ≤1.0
application
100 Base - T4
100 Base - TX
100 VG - AnyLAN
155 Mbps ATM
622 Mbps ATM
Rated temperature 75℃
Conductor stranded bare copper
Wire gauge 14 to 24 awg
Sheathed polyvinyl chloride
The conductor is stranded with bare copper wire
Wire gauge 10 to 22
Insulating polyvinyl chloride
Some 2-6
Shielding polyester + hose (ointment)+ aluminum foil
Sheath linear low density polyethylene
Tear the rope as needed
application
Audio/control
Outdoor applications
External communication system
The test results
LLDPE elongation (%) ≥250
Preaging tensile strength (Mpa) ≥13.8
Aging elongation (%) ≥100
Aging condition (℃ XHRS) 100℃x168
Post-aging tensile strength (Mpa) ≥85 unaged
Aging elongation (%) ≥50 unaged
Cold bending (-40℃x4hrs) No Crack
packaging
500ft//box or 1000ft/box